Get €500 (or $500) on your prepaid balance! Use it for premium subscriptions or job postings. Read more Close

Recalls of Arthroscopic Equipment After Food and Drug Administration 510(k) Approval: A Twenty-Year Analysis of Causes, Trends, and Time to Recall (2004 to 2024).

Created on 05 Sep 2025

Authors

Thriaksh Rajan, Christian J Hecht, Comron Saifi, Prem N Ramkumar, Justin R Mistovich

Published in

The Journal of the American Academy of Orthopaedic Surgeons. Aug 28, 2025. Epub Aug 28, 2025.

Abstract

Current reliance on the expedited 510(k) approval pathway has driven rapid commercial availability of novel arthroscopic devices. Despite the low complication rates of arthroscopic procedures, products from this pathway are suspected to increase the rate of recalls and device malfunctions.
This study aimed to characterize arthroscopic device recalls, analyze trends in recall incidence, and identify predictors of time to recall.
A 20-year, retrospective, cross-sectional study was conducted using the Food and Drug Administration (FDA) Recalls database. Recalled devices approved under the FDA 510(k) pathway were identified and categorized by type, manufacturer, recall class, and cause. Statistical analyses included Poisson regression for trends and Cox proportional hazards modeling for predictors of time to recall.
A total of 124 recalls were initiated during the study period (average 6.2 recalls/year), with packaging and process control issues accounting for 50.7% of recalls. Recall incidence remained stable over time, although nearly half occurred in 2008, 2010, 2012, and 2019. Mean recall time was 491 days (95% confidence interval [CI], 444 to 539). Devices recalled due to material/implant contamination had markedly shorter times (HR: 3.73 [95% CI, 1.78 to 7.82]), whereas process control issues prolonged recall times (HR: 0.56 [95% CI, 0.31 to 1.00]). Manufacturer was another predictor of time to recall, with one manufacturer exhibiting substantially extended recall times (HR: 0.45 [95% CI, 0.22 to 0.92]).
Arthroscopic device recalls are largely caused by packaging and process control issues, emphasizing the need for stricter quality assurance during manufacturing. Although recall incidence remained stable over the past two decades, variability in recall times highlights opportunities for improved manufacturer accountability and FDA oversight. Increasing procurement scrutiny, enhancing FDA audit practices, and integrating recall data with clinical outcomes can minimize disruptions in arthroscopic surgery.
Level III Therapeutic Study.

PMID:
40906998
Bibliographic data and abstract were imported from PubMed on 05 Sep 2025.

Read full publication at:
Please sign in to see all details.

Stats

  • Community rating n/a 0 votes
  • Reviewers' rating n/a 0 votes
  • Your rating

1-terrible, 9-excellent. How would you rate this publication? Sign in in to submit your rating.

  • Recommendations n/a n/a positive of 0 vote(s)
  • Views 1
  • Comments 0

Recommended by

  • No recommendations yet.

Post a comment

You need to be signed in to post comments. You can sign in here.

Comments

There are no comments yet.

Loading ad...